Authors: Deokar Vinayak Hindurao, D.S.Chavan
In the field of competition, all companies should supply their goods and services with high quality, in shortest period with lower prices than its competitors in order to keep their capacity and power to compete .Plug valves are machine elements which are commonly used for regulation of fluid, semi-liquid and granular medium flow on variety of tanks and pipeline systems. This paper discusses FEA analysis of Plug–valve body followed by Experimental stress analysis using strain gauge method for weight optimization. New optimized models were prepared on the basis of validation of the results obtained from stress analys is procedure. The weight reduction is done by changing the wall and rib thickness. The results clearly shows the maximum weight reduction is 24.86 kg (5.26%) weight of original weight while keeping maximum stress level up to 168.6 N/mm2 which is safe for the applied load.
Comments: 5 Pages.
Download: PDF
[v1] 2012-08-19 07:19:35
Unique-IP document downloads: 1385 times
Vixra.org is a pre-print repository rather than a journal. Articles hosted may not yet have been verified by peer-review and should be treated as preliminary. In particular, anything that appears to include financial or legal advice or proposed medical treatments should be treated with due caution. Vixra.org will not be responsible for any consequences of actions that result from any form of use of any documents on this website.